簡要描述:塑料薄膜介電擊穿/絕緣材料耐電壓強度測試儀高壓機械限位:如果軟件系統(tǒng)失去控制,電壓繼續(xù)往上升,到高壓限位后自動歸零如果在擊穿后未判停,通過過流保護器采集數(shù)據(jù)保證電壓自動歸零有高壓指示燈,通過觀察指示燈的狀態(tài)來判斷實在升壓還是在零位如果長時間做實驗,為保證設備的良好運行,設備留有變壓器排氣口,保證變壓器的良好運行,增長使用壽命如果在實驗中,試樣有異味或者出現(xiàn)燃燒和冒煙現(xiàn)象,可以通過排風系統(tǒng)進行排除。
產(chǎn)品分類
Product Category詳細介紹
品牌 | AIRTIMES/中航時代 |
---|
ZJC-150KV計算機控制塑料薄膜介電擊穿/絕緣材料耐電壓強度測試儀
ZJC-150KV computer controlled voltage breakdown tester
一、應用范圍:
One, application range:
ZJC-150KV主要適用于固體絕緣材料工頻電壓擊穿的測試如電線套管、樹脂和膠、浸漬纖維制品、云母及其制品、塑料、薄膜復合制品、陶瓷和玻璃等介質在工頻電壓或直流電壓下?lián)舸姸群湍碗妷簳r間的測試;擊穿電壓、介電強度測試儀器采用計算機控制,可對介電強度試驗過程中的各種數(shù)據(jù)進行快速、準確的采集、處理,并可存取、顯示、打印。
ZJC-150KV is mainly applied to the test of power frequency voltage breakdown of solid insulating materials such as wire sleeve, resin and rubber, impregnated fiber products, mica and its products, plastic, film composite products, ceramics and glass, etc., which can be used in the test of power frequency voltage or DC voltage.
二、滿足標準:
Two, meet the standard:
1、GB1408.1-2006《絕緣材料電氣強度試驗方法》
1, GB1408.1-2006 "electrical strength test method for insulation materials"
2、GB1408.2-2006《絕緣材料電氣強度試驗方法 ,第2部分:對應用直流電壓試驗的附加要求》
2, "GB1408.2-2006 electrical strength of insulating materials test methods, part second: Additional requirements for the application of DC voltage test"
3、GB/T1695-2005《硫化橡膠工頻擊穿電壓強度和耐電壓的測定方法》
3, GB/T1695-2005 "vulcanized rubber power frequency breakdown voltage strength and resistance to voltage measurement method"
4、GB/T3333電纜紙工頻電壓擊穿試驗方法
4, GB/T3333 cable paper power frequency voltage breakdown test method
5、HG/T 3330絕緣漆漆膜擊穿強度測定法
5, HG/T 3330 insulating paint film breakdown strength test method
6、GB12656 電容器紙工頻電壓擊穿試驗方法
6, GB12656 capacitor paper power frequency voltage breakdown test method
7、ASTM D149《固體電絕緣材料工業(yè)電源頻率下的介電擊穿電壓和介電強度的試驗方法》
7, D149 ASTM "test method for dielectric breakdown voltage and dielectric strength of the dielectric breakdown voltage at the industrial power supply frequency of the solid electrical insulation material"
三、主要技術指標:
Three, the main technical indicators:
1、輸入電壓: AC220V 50Hz ;
1, input voltage: AC220V 50Hz;
2、輸出電壓: AC:0~150kV; DC:0~150kV;
2, output voltage: AC:0 ~ 150kV ~ 150kV; DC:0;
3、輸出功率:15kVA;
3, output power: 15kVA;
5、測量誤差: ≤ 5%;
5, the measurement error is less than 5%;
6、升壓速率:1kV/s~3kV/s;
6, boost rate: 1kV/s ~ 3kV/s;
7、耐壓時間: 0~4H;
7, pressure time: 0 ~ 4H;
8、漏電流 : 1~30 mA可由計算機軟件自由進行設定;
8, the leakage current: 1 ~ 30 mA can be set free by computer software;
9、電源:交流220V±10%的單相交流電壓和50Hz±1%的頻率;
9, power: AC 220V + 10% single-phase AC voltage and frequency of 50Hz 1%;
10、試驗環(huán)境溫度: 15 ~ 30℃,相對濕度:0~85%能夠穩(wěn)定運行;
10, test environment temperature: 15 ~ 30, relative humidity: 0 ~ 85% can be stable operation;
11、外形尺寸長×寬×高:1980mm×1220 mm×1750mm;
11, the shape of the size of a long x x x x x x x x x x x x x x x x x x x x x x x x;
12、設備自重:350Kg;
12, equipment weight: 350Kg;
13、接地要求儀器需要單獨接地,接地附合國家標準要求,金屬棒深埋地下至少要1.5米以下;
13, grounding requires that the instrument need to be alone, the ground attached to the national standard requirements, metal rods deep underground at least 1.5 meters below;
四、性能特點:
Four, performance characteristics:
1、高壓變壓器主要產(chǎn)生試樣所需的直流電壓;
1, high voltage transformer mainly produces the sample required for the DC voltage;
2、調(diào)壓器用于調(diào)節(jié)升壓變壓器輸入端電壓以產(chǎn)生高壓所需的輸入電壓;
2, the regulator is used to adjust the input voltage of the boost transformer to generate the input voltage required by the high voltage;
3、電壓測量主要是從高壓變壓器測量端測量,高壓變壓器測量端和高壓端是線性的;
3, voltage measurement is mainly from the measurement of high voltage transformer, high voltage transformer measurement and high voltage side is linear;
4、放電系統(tǒng)在試驗做完以后放電,以免產(chǎn)生放電對人身的危害;
4, the discharge system in the test after the discharge, so as to avoid the discharge of human body damage;
五、計算機系統(tǒng)及軟件包:
Five, computer system and software package:
1、試驗軟件是我公司研發(fā)的功能強大、操作簡單、顯示直觀的試驗軟件系統(tǒng)。
1, testing software is the latest research and development of our company is powerful, simple operation, display and intuitive test software system.
2、采用計算機控制通過人機對話方式,完成對絕緣介質工頻電壓擊穿,工頻耐壓試驗。
2, the use of computer control through the man-machine dialogue, the completion of the insulation medium power frequency voltage breakdown, power frequency withstand voltage test.
3、試驗過程中可動態(tài)繪制出試驗曲線,試驗的曲線可以多種顏色疊加對比,局部放大,曲線上任意一段可進行區(qū)域放大分析;
3, the test process can be drawn from the test curve, the curve can be a variety of color overlay contrast, local amplification, a section of the curve can be amplified in any region;
4、可對試驗數(shù)據(jù)進行編輯修改,靈活適用;
4, can be used to edit and modify the test data, flexible application;
5、試驗條件及測試結果等數(shù)據(jù)可自動存儲;
5, test conditions and test results and other data can be automatically stored;
6、試驗報告格式靈活可變,適用于不同用戶的不同需求;
6, the test report format is flexible, suitable for different needs of different users;
7、可對一組試驗中曲線數(shù)據(jù)的有效與否進行人為選定;
7, can be used for a set of test data in the effective or not for the selection of human;
8、試驗結果數(shù)據(jù)可導入EXECL,WORD文檔編輯;
8, test results data can be imported into WORD, EXECL document editing;
六、安全說明:
Six, safety instructions:
1、介電強度儀器設備要安裝單獨的保護地線。接保護地線,主要是減少試樣擊穿時對周圍產(chǎn)生的較強的電磁干擾。也可避免控制計算機失控。
1, the dielectric strength of the instrument equipment to install a separate ground wire. Earth wire, mainly to reduce the sample breakdown of the strong electromagnetic interference around the. Can also avoid control computer control.
2、該介電強度儀器設備的電路設有多項保護措施,主要有:過流保護、失壓保護、漏電保護、短路保護、直流試驗放電報警等。
2, the dielectric strength of the instrument and equipment of the circuit with a number of protective measures, mainly include: over current protection, loss of voltage protection, leakage protection, short circuit protection, DC test discharge alarm, etc..
3、安全保護:
3, safety protection:
(1)門限位保護:不關門,即使通電點實驗開始,設備無任何反應,軟件有:安全門未關閉提示。
(1) the threshold level protection: do not close the door, even though the power point experiment, the device has no any response, the software is: the safety door is not closed.
(2)電壓歸零保護:如果在實驗過程中,突然斷電,下次開機后,會自動回到零位,保證初始電壓為在零位
(2) the voltage to zero protection: if the experimental process, the power, the next boot, will automatically return to zero, to ensure that the initial voltage is zero
(3)終止電壓保護:可以通過軟件設定終止電壓,保證在升壓過程中如果出現(xiàn)異常升到的電壓后,自動終止并歸零
(3) termination voltage protection: it can be set by the software to terminate the voltage, to ensure that in the process of the rise in the event of abnormal rise to the specified voltage, automatic termination and return to zero
(4)高壓機械限位:如果軟件系統(tǒng)失去控制,電壓繼續(xù)往上升,到高壓限位后自動歸零如果在擊穿后未判停,通過過流保護器采集數(shù)據(jù)保證電壓自動歸零有高壓指示燈,通過觀察指示燈的狀態(tài)來判斷實在升壓還是在零位如果長時間做實驗,為保證設備的良好運行,設備留有變壓器排氣口,保證變壓器的良好運行,增長使用壽命如果在實驗中,試樣有異味或者出現(xiàn)燃燒和冒煙現(xiàn)象,可以通過排風系統(tǒng)進行排除。
(4) high voltage mechanical limit: if the software system is out of control, the voltage continues to rise, to the high voltage limit automatically after the breakdown of the non stop, through the flow protection device to collect data to ensure that the voltage automatically to zero with high pressure indicator, through the observation of the status of the test, to ensure the good operation of equipment, equipment to keep a good run, the growth of the use of life in the experiment, if the sample has a smell or smoke phenomenon, can be excluded through exhaust system.
(5)獨立接地保護
(5) independent grounding protection
(6)短路保護
(6) short circuit protection
(7)軟件誤操作保護
(7) software error protection
(8)漏電保護
(8) leakage protection
(9)實驗結束放電保護
(9) the end of the experiment is to end the discharge protection
產(chǎn)品咨詢
歡迎您關注我們的微信公眾號了解更多信息
電話
微信掃一掃